Implementation Image Analysis and Optimization Techniques in e-Medicus System DOI:10.15199/48.2018.01.24

Czytaj za darmo! »

In this paper. gradient reconstruction algorithms, medical and stereoscopic images in e-Medicus system were implemented. The reconstruction problem is a nonlinear and ill-posed, whose solution calls for special regularized algorithms [6-8]. In many cases the linear systems arising in practice consist of real number coefficients and data. The image reconstruction is very sensitive to the ubiquitous modelling errors which are caused by inaccurately known auxiliary variables of the measurement model [21-25]. Figure 1 presents the model of the imaging system. Fig. 1. The model of the imaging system The image data is of immense practical importance in medical informatics. Medical images, such as Computed Axial Tomography (CAT), Magnetic Resonance Imaging (MRI), Ultrasound, and X-Ray, in standard DICOM formats are often stored in Picture Archiving and Communication Systems (PACS) and linked with other clinical information in EHR clinical management systems. Research efforts have been devoted to processing and analysing medical images to extract meaningful information such as volume, shape, motion of organs, to detect abnormalities, and to quantify changes in follow-up studies. Recent advances in a wide range of medical imaging technologies have revolutionized how we view functional and pathological events in the body and define anatomical structures in which these events take place. X-ray, CAT, MRI, Ultrasound, nuclear medicine, among other medical imaging technologies, enable 2D or tomographic 3D images to capture in-vivo structural and functional information inside the body for diagnosis, prognosis, treatment planning and other purposes. Stereoscopic images Stereoscopic imaging techniques allow for 3D images. Simultaneous recording of two images allows for the mutual dependence of the spatial object, the distance from the observer and the depth of the scene. In order to obtain stereosc[...]

ECT Measurement System with Optical Detection for Quality Control of Flow Process DOI:10.15199/48.2016.12.40

Czytaj za darmo! »

Multi-phase flow measurement technologies are still built and improved. There is a clear trend in the industry to implement more optimum related functions, where the focus is put on an active control and the monitoring system. Control related active optimum functions can only be realised with a system that allows the electronic control. Electrical capacitance tomography (ECT) is a method of imaging cross-sections of vessels and pipelines containing dielectric material. Permittivity distribution is determined with a multi-electrode sensor and interpreted by software. This paper provides description of the device as well as results of exemplary measurements. Streszczenie. Technologie pomiarowe przepływu wielofazowego są wciąż budowane i ulepszane. Istnieje wyraźna tendencja w przemyśle do realizacji funkcji związanych z bardziej optymalnym sterowaniem, w którym nacisk kładziony jest na aktywną kontrolę i system monitoringu. Optymalizacja funkcji do aktywnej kontroli może być realizowana tylko w systemie, który umożliwia sterowanie elektroniczne. Elektryczna tomografia pojemnościowa (ETP) jest metodą obrazowania przekrojów naczyń i rurociągów zawierających materiał dielektryczny. Przenikalność elektryczna jest wyznaczana za pomocą czujnika wieloelektrodowego i interpretowana przez oprogramowanie. Niniejszy dokument zawiera opis urządzenia, jak również przykładowe wyniki pomiarów.(System pomiaru ETP z optyczna detekcją do kontroli jakości procesów przepływu). Keywords: Electrical Capacitance Tomography, Image Analysis, Sensors Słowa kluczowe: elektryczna tomografia pojemnościowa, analiza obrazów, sensory Introduction Simple and low cost intrusive probes have been used in many operation systems to obtain flow information. Process tomography becomes even more appealing when nonintrusive sensors are used to obtain the cross-sectional images. Designed control system allows for correlative studies using sets of measuring electrodes (Fig. 1). The [...]

Electrical Capacitance Tomography and Optical Detection in Quality Control System DOI:10.15199/48.2017.12.53

Czytaj za darmo! »

Modern production processes are increasingly complex, while customers are demanding higher quality products at the lowest price. This situation increases the importance of process optimization. Products and requirements are changing faster and faster, technologists have less and less time to learn the process and to optimize it solely on the basis of their own experience. On the other hand, very often the processes are automated and metered in detail, so we have plenty of data describing it. Analysis of the data may be used for process optimization in different ways and it can affect many aspects of process management. We can detect disturbances in the process, find the causes affecting the problems with quality, and choose the optimal settings for the process, comparing different preparation procedures and many others. It is worth noting that in the processes, there are many people involved in with different tasks and permissions. Therefore, data analysis tool should provide access control. The research project assumes creation of two measurement platforms: a set of multiphase flow system and a mini production line. In the first case we will be analysing two-phase flows of liquid (water) and air. That type of flow is commonly used in chemical reactors where air is mixing substances [4,9,10]. Electrical Capacitance Tomography Electrical capacitance tomographs are devices capable of performing analysis of pipeline fragment or a vessel filled with examined medium [15]. Obtained cross-section’s image reconstruction can be analysed further for an automated quality control system’s autonomous and correct decision. However, existing industrial solutions are still of significant size and structurally complex [2,4,5]. This fact greatly limits the number of actual deployments. Decision makers are afraid of electrical capacitance tomography (ECT) implementation due to high costs of possible equipment failures and because[...]

Moisture Wall Inspection Using Electrical Tomography Measurements DOI:10.15199/48.2018.01.25

Czytaj za darmo! »

One of the major causes of pathologies in historic buildings all over the world is the presence of moisture, particularly rising damp. Moisture transfer in walls of an old buildings, which are in direct contact with the soil, leads to a migration of soluble salts responsible for many building problems. Building porous materials (e.g. brick or concrete), both natural and manufactured have pores (like a sponge) and the moisture can be pulled up against gravity (capillary effect). Rising damp from the soil is a problem in old buildings, especially without adequate horizontal and vertical insulation of foundations. Moisture creates a danger not only to the walls, but also to human health. It promotes progress of rheumatic disorders and formation of fungus on the walls. Fungus can cause allergies and many other diseases. There are many different drainage systems (dry as watertight barriers, injection of hydrofuge products, etc.). Regardless of the method it is very important to continuously monitor the status of damp during the drying process [5]. The models of a brick wall are presented in Fig. 1. The test results obtained by the non-destructive impedance tomography are compared with the results obtained by numerical simulations. There were prepared two prototype measuring systems (16 and 32 electrodes). First of them is a system contains the 16 electrodes for measuring damp brick wall on one side (Fig. 1a). Second one is a system with 32 electrodes for test on both sides of wall (Fig. 1b). Measurement systems The electrical tomography (ET) is a technique of imaging the [...]

Efektywny algorytm obrazowania w tomografii ultradźwiękowej i radiowej dla zagadnień dwuwymiarowych DOI:10.15199/48.2018.06.11

Czytaj za darmo! »

W ostatnich latach obserwujemy dynamiczny rozwój Tomografii niekonwencjonalnej jak na przykład dyfuzyjnej tomografii optycznej [12,13,16]. Przez tomografię konwencjonalną, autorzy rozumieją tomografię o ustalonym zasięgu zastosowań w medycynie czy też przemyśle, jak na przykład tomografię rentgenowską, tomografię rezonansu magnetycznego czy tomografię ultradźwiękową nazywaną powszechnie USG. Ta ostatnia coraz śmielej stosowana jest w przemyśle [4,10]. Również tomografia fal z radiowego zakresu jest ostatnio coraz chętniej stosowana [2,3,9,17]. Transmisyjną tomografię ultradźwiękową i radiową tomografię łączy jedna wspólna cecha. Fale ultradźwiękowe i radiowe, rozchodzą się po liniach prostych. Wykorzystując tę cechę, zaproponowano efektywną modyfikację istotnego fragmentu dobrze znanego w literaturze algorytmu algebraicznej rekonstrukcji obrazu (ang. Algebraic Reconstruction Techniques (ART)), zaproponowanego po raz pierwszy przez S. Kaczmarza [5,6,7,15]. Istota tej modyfikacji polega na przybliżeniu kształtu piksela, (który do tej pory traktowany był jako kwadratowa komórka), do kształtu kołowego. Zmiana ta pozwala w sposób istotny przyspieszyć metodę wyznaczania pikseli, przez które przechodzi dany promień w rozpatrywanym obszarze. Dzięki temu w zagadnieniach 2D uzyskujemy znaczne przyspieszenie obrazowania, co ma szczególne znaczenie w przypadkach, kiedy zależy nam na obrazowaniu "on line". Zysk czasowy będzie jeszcze większy dla zagadnień 3D, ale będzie to przedmiotem osobnego artykułu. Metody algebraiczne obrazowania tomograficznego Większość algorytmów z grupy algebraicznych technik rekonstrukcyjnych - ART bazuje na metodologii aproksymacji funkcji przez szeregi o skończonej długości [6,15]. W metodach tych dokonuje się uproszczenia polegającego na przyjęciu, że rekonstruowany obraz składa się ze skończonej liczby elementów. Obraz odtwarzany jest za pomocą algorytmu dyskretyzującego badany obszar do postaci n kwa[...]