Partial discharge of oil-paper insulation under DC voltage superimposed AC voltage

Czytaj za darmo! »

The insulation of converter transformer is stressed by AC and DC voltages. To investigate partial discharge (PD) characteristic of oilpaper insulation, this paper designed a power source system of DC superimposed AC voltage. The testing sample is an air gap model in the middle of an insulation cardboard .A broadband current transformer is used to measure PD current recorded by an oscilloscope with a bandwidth of 5 GHz. Experiments are performed under AC,DC only, and DC superimposed AC voltages with the sample immersed in transformer oil. using electrode configurations that is parallel plate. The single PD pulses are anglicized by ORIGIN software. It is realized that the impulse current signals generated due to partial discharges under AC and DC voltages are different with amplitude, rise time, counts, duration and energy content PD pulse under AC voltage is of long duration pulse compared to that generated under DC voltage, and the PD pulse under DC superimposed AC voltage is stochastic. The key point is the moment (phase position) PD occurring moves to the zero point of the applied voltage than the case only under ac voltage. These will contribute to the development of effective PD monitoring systems for oil-insulated converter transformer. Streszczenie. Izolacja transformatorów w przekształtnikach jest narażona na napięcia AC i DC. Przeprowadzono analizę wyładowań niezupełnych w izolacji z papieru olejowego w systemach napięcia stałego z obecnością składowej przemiennej. Zarejestrowano wyładowania przy użyciu oscyloskopu o paśmie 5 GHz. Badania przeprowadzona dla napięcia DC, AC oraz DC plus AC. Impulsy prądu wyładowań mają inną amplitudę, czas narastania i energię w zależności od rodzaju napięcia. Istotną sprawą jest napięcia. Zaproponowano efektywna metodą monitorowania jakości izolacji transformatorów w przekształtnikach. (Wyładowania niezupełne w izolacji z papieru olejowego pod wpływem napięcia stałego ze składową przemienną). Keyword[...]

The study of phased-ultrasonic receiving-planar array transducer for PD location in power transformer

Czytaj za darmo! »

Partial discharge (PD) is the main cause of electric equipment degradation. PD location can provide the scientific direction and analysis for equipment condition monitoring. The phased-ultrasonic receiving-planar array transducer for PD location in transformer is studied in this paper. The operation environment and material properties of transducer are analyzed. The center frequency of transducer is 150 kHz and its bandwidth is 100 kHz. The piezoelectric source and oil interstitial defect are used to detect the transducer’s performance in lab. Experimental results show the transducer has perfect ultrasonic receiving characteristics. The successful developments of this sensor provide a good foundation for PD location in transformer using phased-ultrasonic receiving-planar array transducer. Streszczenie. Wyładowania niezupełne są częstą przyczyną uszkodzeń urządzeń elektrycznych. W artykule przedstawiono ultradźwiękowy przetwornik o czestotliwości 150 kHz zaprojektowany do lokalizacji wyładowań niezupełnych. Preprowadzne eksperymenty dowiodły przydatności takiego przetwornika. (Badania odbiornika ultradżwiękowego w zastosowaniu do lokalizacji wyładowań niezupełnych w transformatorach) Keywords: partial discharge, ultrasonic, array transducer, PD location. Słowa kluczowe: wyładowania niezupełne, przetwornik ultgradźwiękowy. 1. Introduction Partial discharge (PD) is the main cause of insulation degradation in power transformers and is an important item of insulation detection. By locating PD inside the transformer, appropriate guides and suggestions can be made to eliminate failures and to carry out maintenance. Partial discharge produces electrical pulse, electromagnetic radiation, ultrasonic, light, some new products, partial overheating, etc. Theoretically the above phenomena, if detectable, can be used as incitements of PD defects [1]. Promising developments have been made in PD location, including electro pneumatic location, ul[...]

Simulation of Cross-shaped Ultrasonic Array Applied to Partial Discharge Location in Oil

Czytaj za darmo! »

A study on a combined sensor was made for partial discharge(PD) location in oil. The sensor includes a cross-shaped ultrasonic phased array of 13 elements and an ultra-high frequency (UHF) electromagnetic conformal array of 4 elements. The ultrasonic array can achieve the array performance of 61 elements with high-order cumulant processing technology. It can improve the array aperture and direction sharpness of the sensor and greatly reduce the following circuit and manufacturing costs. The method of PD location which use expanded ultrasonic array accompanied with UHF electromagnetic array has better location performance. The spatial spectrum comparing with MUSIC(multiple signal classification)method shows that virtual expanding array of the fewer number array elements with high-order cumulant processing technology has strong ability to suppress colored Gaussian noise interference. This provides the possibility for the practical application of array technology in power equipment. Streszczenie. Zaprezentowano czujnik do badania wyładowania niezupełnego w oleju. Czujnik składał się z matrycy 13 czujników ultradźwiękowych I 4 wysokoczęstotliwościowych czujników elektromagnetycznych. Matryca czujników może spełniać rolę wirtualnej matrycy złożonej z 61 elementów. (Matryca krzyżowych czujników ultradźwiękowych do badania wyładowania niezupełnego w oleju) Keywords: partial discharge; high-order cumulant; noise suppression; virtual array expansion. Słowa kluczowe: wyładowanie niezupełne, czujniki ultradźwiękowe. Introduction Partial discharge is the major reason resulting in insulation deterioration for the power equipment, especially for the power transformer. PD monitoring is also an important part of intelligent monitoring equipment online. The PD parameters are greatly affected by the location of the PD sources in power equipment. Fixing the PD location can reflects the insulation condition. It can make the maintenance strategy bett[...]

 Strona 1